Ingressus
Ingressus IV with R2c Door Access Separated Power Supply for Each Door Wiring Diagram
The FingerTec Ingressus IV door access provides a computerised central control access control system to secure the environment. Ingressus can store fingerprints, password and card ID of every user. It justifies accessibilities of every user according ...
Ingressus IV and Slave Devices
Introduction Ingressus IV is FingerTec’s latest advance access controller which supports access control up to 4-doors. In short, Ingressus IV can be described as a 4-In door controller. A total of 4 Wiegand input ports is available in Ingressus IV. ...
Activating the Door Closure Delay Siren in Ingressus
Introduction Security is an important aspect in every organization nowadays. Improper security measures may cause bigger problems such as robbery, data theft or even endanger the safety of a person. Even with the proper access control products ...
Activating the Close and Reverse State in Ingressus
Introduction Sometimes, the security of an office can be easily compromised if the door is not locked once it is closed. This situation can lead to unauthorized access and break-ins. However, the FingerTec’s Ingressus controller has a feature that ...
Configuring Fire Alarm in 2 Ingressus to Open All Doors when Smoke Sensor is Triggered
Introduction Ingressus can be integrated with multiple auxiliary inputs and outputs. One of the main safety features of Ingressus is that it can be combined with smoke sensors in an event of fire to trigger alarm alert and to open all doors of your ...
Ingressus 4 In/Out Device : K-Kadex / I-kadex pair with R2c / R3c
Introduction Ingressus IV is a controller that supports access control for 4 doors. By default, the Ingressus IV only supports 1 Wiegand device for each door as In-device. However, by using RS485 slave, we can make the setup to have an Out-device. ...
Configuring Fire Alarm in Two Pieces of Ingressus to Open All Doors when Smoke Sensor is Triggered
Introduction Ingressus can be integrated with multiple auxiliary inputs and outputs. One of the main safety features of Ingressus is that it can be combined with smoke sensors in an event of fire to trigger alarm alert and to open all doors of your ...
Use Ingressus Controller with Fire Alarm System for Better Emergency Management
Introduction A fire alarm system is a variety of devices connected together to identify and alert people through visual and audio appliances when smoke, fire, carbon monoxide gas or other emergency situations are present. These alarms might be ...
Prevent Duplicate Password During Enrollment Process (Ingressus Controller / k-Kadex)
Introduction: Ingressus controller is a device that is developed to be paired with a slave device, such as k-Kadex. To ensure that the Ingressus Controller is always functioning properly with k-Kadex, we’ve prepared this article to explain how to ...
How The Long Range Reader Works With Ingressus Controller
Introduction On Vehicle Access Control: Vehicle Access Control System is a security control method that can be utilized to allow the access of transportation vehicles such as cars into a compound. In access control systems, users are required to ...
How To Configure Ingressus For Fire Alarm System
Introduction: FingerTec Ingressus I,II and IV devices have the capability to support all doors in opening and closing them when the alarm is triggered in case of an emergency such as a fire. Basically, Ingressus has an auxiliary input that can be ...
How to Setup Interlocking in Ingressus
Introduction For higher-level security, interlocking is the fundamental parts of door access security where two doors are interconnecting, where each of the doors must entirely close before one could access another door. This feature is to prevent ...
Ingressus Metal Casing Setup
Introduction Ingressus controllers are designed to control access for a one-door (Ingressus I), two-door (Ingressus II) and four-door environment (Ingressus IV). With Ingressus, a user needs to verify his identity at a Wiegand terminal or an RS485 ...
Fire Alarm System Integration with FingerTec Terminal Wiring Diagram
Introduction Exit routes for emergencies are important for every building when there are fires or other incidents. Regarding fire safety, most buildings have a fire alarm system as part of a full security system. With a Fire Alarm System, doors with ...