Ingressus IV and Slave Devices

Ingressus IV and Slave Devices

Introduction
Ingressus IV is FingerTec’s latest advance access controller which supports access control up to 4-doors. In short, Ingressus IV can be described as a 4-In door controller. A total of 4 Wiegand input ports is available in Ingressus IV.

It links up with 4 units of 26-bits Wiegand readers (iKadex or kKadex) to capture card ID or password details as access credentials. The role of each Wiegand reader is to control their designated door to limit the “in” access. Thus, there must be a push release button (some called it REX, request exit button) installed inside to unlock the door and exit the zone that it was assigned under.

Through the implementation of this system, users will only need to verify their credentials once when coming into a zone and they are free to leave from a different zone so long as an anti-passback isn’t in place. Hence, we called it the 4-In doors controller. The reason why it is labelled as such is because of the connection between the In and Out devices:

In device

Out device

Apply to

kKadex/iKadex

Push release button

1

kKadex/iKadex

Push release button

2

kKadex/iKadex

Push release button

3

kKadex/iKadex

Push release button

4


However, do note that advance access control features such as anti-passback, interlocking, multi users unlock and unlock combination will still take effect in Ingressus IV.

In order to unleash the full power of Ingressus and control In-Out access at all 4 doors, you can link up with 8-units of RS 485 reader (R2c). Each door will be secured by 2 units of R2c and this will limit all the in-out activities.

The slave fingerprint scanner is capable of capturing fingerprints and card details as access credentials for its master, the Ingressus, to verify. The R2c communicates with Ingressus via the RS485 network. Each R2c comes with a “dip-switch” to identify its ID number, ranging from 1 to 8. The connection between each ID and door are as below:


The ID of R2c for In


The ID of R2c for Out


Apply to


1


2


1


3


4


2


5


6


3


7


8


4


In the case of budget or special requirements, you may mix and match the slave devices with R2c, kKadex, iKadex and push release button to secure the doors. For example:


In device


Out device


Apply to


kKadex/iKadex


Push release button


1


R2c (ID 3)


R2c (ID 4)


2


kKadex/iKadex


Push release button


3


R2c (ID 7)


R2c (ID 8)


4


Kindly ensure that you set the correct “dip-switch” at R2c so that Ingressus can identify its position.

Note: If some of the screenshots or steps viewed here are different from the ones in the current system, this is due to our continuous effort to improve our system from time to time. Please notify us at info@timeteccloud.com, we will update it as soon as possible.




    • Related Articles

    • Ingressus IV with R2c Door Access Separated Power Supply for Each Door Wiring Diagram

      The FingerTec Ingressus IV door access provides a computerised central control access control system to secure the environment. Ingressus can store fingerprints, password and card ID of every user. It justifies accessibilities of every user according ...
    • Ingressus 4 In/Out Device : K-Kadex / I-kadex pair with R2c / R3c

      Introduction Ingressus IV is a controller that supports access control for 4 doors. By default, the Ingressus IV only supports 1 Wiegand device for each door as In-device. However, by using RS485 slave, we can make the setup to have an Out-device. ...
    • How to pair FingerTec QR110 Slave Reader with FingerTec Master Readers

      Introduction QR110 QR Code Scanner is FingerTec latest product that comes with a new verification method: QR Code along with the capabilities to scan RFID/MiFare access cards as well. As a slave reader, QR110 will need to be paired with FingerTec ...
    • How to Setup Interlocking in Ingressus

      Introduction For higher-level security, interlocking is the fundamental parts of door access security where two doors are interconnecting, where each of the doors must entirely close before one could access another door. This feature is to prevent ...
    • Ingressus Metal Casing Setup

      Introduction Ingressus controllers are designed to control access for a one-door (Ingressus I), two-door (Ingressus II) and four-door environment (Ingressus IV). With Ingressus, a user needs to verify his identity at a Wiegand terminal or an RS485 ...